Connect Modbus RTU Servers to an Allen-Bradley PLC

Easily connect up to 32 Modbus RTU server devices to an Allen-Bradley PLC

SKU: 460ETCMM

460ETCMM

$NZD 1,346.75 - $NZD 1,916.42

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Get Your Modbus RTU Server Devices Connected Directly to the Data Table of Your Allen-Bradley PLC

The 460ETCMM moves data between up to 32 Modbus RTU server devices and up to five different Allen-Bradley PLCs. It’s the perfect tool to help save legacy Modbus RTU devices from the scrap pile and also allows you to use the plethora of Modbus RTU devices available in your Allen-Bradley PLC architectures.

Best of all the product is made in the USA, is always in stock and comes with 5-year warranty.

How Does the Data Move In and Out of the PLC?

You allocate two areas of tags or register blocks in your Allen-Bradley PLC. One area is a user-defined set of write-only tags or register blocks accepting data from your Modbus RTU devices. The other area is full of read-only tags or register blocks to send data to your Modbus RTU devices. You directly map Modbus RTU register and coil data into read and write locations in the data table of your Allen-Bradley PLC.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to three mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?

The 460ETCMM provides an option to access Modbus RTU server devices without having to upgrade your PLC or get an expensive in rack solution. While there are certainly a number of other companies offering standalone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us. Try the RTA difference today.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

EtherNet/IP Tag Client Features

PLC Support: ControlLogix, CompactLogix, FlexLogix, MicroLogix, SLC’s and PLC5E’s
Maximum Number of PLCs Supported: 5
Maximum Number Read Tags or Registers Supported: 150 per PLC
Maximum Number Write Tags or Registers Supported: 150 per PLC
Array Support: Yes, for all data types except strings
Supported Data Types: ControlLogix / CompactLogix / FlexLogix: Bit, 32 Bit Array, SINT, INT, REAL, STRING, DINT, MicroLogix / SLC / PLC5E: 16 Bit Array, INT, REAL, STRING

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.

460ETCMM-N2E
DATASHEET  USERGUIDE
460ETCMM-N2EW
DATASHEET  USERGUIDE
460ETCMM-N34
DATASHEET  USERGUIDE
460ETCMM-N700
DATASHEET  USERGUIDE
460ETCMM-NNA1
DATASHEET  USERGUIDE
460ETCMM-NNA4
DATASHEET  USERGUIDE