Connect Modbus RTU Slave to a Profibus Controller

Connect up to 32 Modbus RTU slave devices to Profibus controller

SKU: 460MMPBS

460MMPBS

$NZD 1,410.82 - $NZD 1,462.97

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Move Modbus RTU Slave Register Data To Your Profibus DP Systems
The 460MMPBS moves data between up to 32 Modbus RTU Slave devices and a Profibus DP enabled PLC. With the 460MMPBS you are making a direct connection between Modbus RTU Slave data and user defined slots in your Profibus DP PLC.

Best of all the product is Made in the USA, is always in stock and comes with a 5 year warranty

How Do You Map the Data?
Modbus RTU Slave Register and coil data will be mapped into 10 Profibus DP slots. The slots will be assigned a type of Int8, int16, int32, int64, UInt8, Uint16, Uint32, Uint64, float, double, binary8, binary16 or binary32.

When writing from your Profibus DP Master to your Modbus RTU devices, the data in the lots can be mapped to registers and coils in any Modbus RTU Slave.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460MMPBS provides an option to access Modbus RTU Slave devices without having to upgrade your PLC or get an expensive in rack solution. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call a live person answers the phone. When you talk with sales you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support it is from an engineer who had a hand in the product’s development and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

Profibus Slave Features

Object Model: 10 Slots in each direction
Slot Size: 2, 4, 8, 16, 24, 32 Bytes
Data Representation: int8, int16, int32, int64, uint8, uint16, uint32, uint64, Float, Double, binary8, binary 16, binary 32, Short String
Total Data Supported: 244 Bytes in each direction
Maximum Profibus DP Connections: 1

Gateway Security
You can configure up to 9 different users access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.