Modbus RTU Slaves to OPC UA

Modbus RTU Slaves to OPC UA

SKU: 460MMUS

460MMUS

$NZD 1,356.26 - $NZD 1,929.93

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Connect to Modbus RTU Devices via OPC UA

The 460MMUS connects 32 Modbus RTU Slave devices with up to 3 OPC UA Clients.

Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How do I use 460MMUS in my application?

Modbus RTU Register and Coil data is mapped to OPC nodes. The data moves bidirectionally.

It’s really that simple to convert data to the information systems you need to monitor your application.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

OPC UA Server Features

Operation Mode: opc.tcp/binary with no Security
Simultaneous Connections Supported: 3
Max Number of Input Nodes per Node Type: 200
Max Number of Output Nodes per Node Type: 200
Array Support: Boolean, Integer, Unsigned Int and Float
Profiles Supported: UA 1.03 Micro Embedded Server and Data Access

Gateway Security
You can configure a user with access to diagnostic and configuration screens.

Status and Counters
Protocol-specific status, counters and error messages are accessible within the gateway's diagnostics page.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol-specific messages and error messages.

460MMUS-N2E
DATASHEET  USERGUIDE
460MMUS-N2EW
DATASHEET  USERGUIDE
460MMUS-NNA1
DATASHEET  USERGUIDE
460MMUS-NNA4
DATASHEET  USERGUIDE