Connect BACnet MS/TP Slaves to Siemens S7 PLCs

The easiest way to connect BACnet MS/TP Slaves to Siemens S7 PLCs!

SKU: 460BMSC

460BMSC

$NZD 1,399.87 - $NZD 1,992.01

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Get BACnet MS/TP Slave Data into your Siemens S7 PLC

The 460BMSC moves data between your BACnet MS/TP slaves to your Siemens S7 PLC.

Best of all, the product is made in the USA, always in stock and comes with 5-year warranty.

How do I use the 460BMSC in my application?

BACnet analog, binary and CSV data segments can be converted to corresponding data
types as your Siemens PLCs and transferred over to them and vice versa.

It’s really that simple. Need to modify your data as it passes from one protocol to the other?
No problem. Each data mapping you apply can be modified with up to three mathematic
functions.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who
provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get
honest answers and recommendations. When you get support, it is from an engineer who
had a hand in the product’s development, and support doesn’t require a ticket or 24-hour
wait.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

BACnet MS/TP Master Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

S7 Client Features

PLC Support: S7 300/400/1200/1500
Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String

Gateway Security
You can configure a user with access to diagnostic and configuration screens.

Status and Counters
Protocol-specific status, counters and error messages are accessible within the gateway's diagnostics page.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol-specific messages and error messages.