Product Description
Control Up To 32 DeviceNet Slave Devices from a Serial PLC5, SLC or MicroLogix PLC
You can now control a network of 32 DeviceNet Slaves from a legacy Allen-Bradley serial DF1 PLC. It’s the perfect tool to save legacy PLCs from the scrap pile and control DeviceNet devices directly from the serial PLC5, SLC and MicroLogix PLCs.
How Do I Use the 460DMDFM in My Application?
For most applications the mapping is very straight forward. PLC data table values, like N7:200 and F9:1, are mapped directly into the Input and Output assemblies of the cyclic data transfer for each DeviceNet Slave connection.
It really is that simple.
Why Use Real Time Automation as a Gateway Supplier?
While there are certainly a number of other companies offering gateways, there is no one who provides the level of support and service that you receive from RTA.
When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait.
Try the RTA difference today.
- Manual
- 3’ power cable with flying leads
- 5-year hardware warranty
- IPSetup software — automatically locates RTA gateway on the network
- Unlimited firmware feature upgrades for life
- CAT5 cross over cable for direct connection to PC during programming
- Complete, unlimited access to our industry leading support staff
DeviceNet Master Features
DeviceNet Operation Modes: UCMM Client, Group 2 Client, Group 2 only Client
Implicit Message Support: Polled only, Assembly Object
Maximum DeviceNet Slave Devices: 32
Data per Slave: 0-400 Bytes in each direction
Supported Data Types: BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, Double
DF1 Master Features
Operation Modes: DFM Full Duplex and DFM Half Duplex
PLCs Supported: MicroLogix 1000, SLC 5/03 5/04 5/05, most PLC5s
Maximum number of Devices supported: 1 in Full Duplex Mode, 32 in Half Duplex
Data Type Supported: 100 Integers or 100 Binaries, or 50 floats, 82 character string per scan line
Scan lines: 100 input, 100 output
Physical Connections: RS485 and RS232
Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.
Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.
Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.
Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.
Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.