Connect Modbus TCP/IP Servers to DeviceNet Slaves

Easily Connect Modbus TCP/IP Servers to DeviceNet Slaves

SKU: 460MCDM

460MCDM

$NZD 1,504.33 - $NZD 1,559.69

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Connect Modbus TCP/IP Server Devices and DeviceNet Slave Devices
The 460MCDM moves data between a network of up to 32 Modbus TCP/IP Server devices and up to 32 DeviceNet Slaves. It’s the perfect tool to tie all of your Modbus TCP/IP devices into your DeviceNet network.

How Do I Use the 460MCDM in My Application?
Up to 100 reads and 100 writes from your Modbus TCP/IP Servers will be mapped into your DeviceNet Slave devices as DeviceNet Data. When writing from your DeviceNet Slaves to your Modbus TCP/IP Servers up to 400 bytes of data per Slave will be mapped to up to 32 Modbus TCP/IP Servers as Modbus TCP/IP data.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?
The 460MCDM provides an option to connect Modbus TCP/IP and DeviceNet networks. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because that means you mean a lot more to us.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus TCP/IP Client Features

Modbus Operation Modes: Modbus TCP/IP Client
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 and 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Server Devices: 32
Number Read/Write Scan Lines per Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

DeviceNet Master Features

DeviceNet Operation Modes: UCMM Client, Group 2 Client, Group 2 only Client
Implicit Message Support: Polled only, Assembly Object
Maximum DeviceNet Slave Devices: 32
Data per Slave: 0-400 Bytes in each direction
Supported Data Types: BIT8, BIT16, BIT32, INT8, INT16, INT32, INT64, UINT8, UINT16, UINT32, UINT64, Float, Double

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.

460MCDM-N34