Connect Modbus TCP/IP to USB

Connects up to 32 Modbus TCP Servers with as many as 2 USB devices

SKU: 460MCUSB

460MCUSB

$NZD 1,468.72 - $NZD 1,523.00

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Get Your USB Barcode Scanners Connected Directly to Your Modbus TCP/IP Server Devices

The 460MCUSB moves data between up to 2 USB devices like barcode scanners and up to 32 Modbus TCP/IP Server devices. It’s the perfect tool to tie your USB devices to your Modbus TCP/IP Servers. Best of all the product is Made in the USA, is always in stock and comes with 5 year warranty.

How Do I Use the 460MCUSB in My Application?

Incoming ASCII data from a USB device is mapped directly to Registers in your Modbus TCP/IP Server devices.

If your device uses delimiters, the 460MCUSB can be configured to automatically remove the delimiters, no need to deal with the delimiters in your Servers. If you need to parse your data, the 460MCUSB can parse a string of ASCII data in up to 50 segments by delimiter or offset.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait. Try the RTA difference today.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus TCP/IP Client Features

Modbus Operation Modes: Modbus TCP/IP Client
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 and 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Server Devices: 32
Number Read/Write Scan Lines per Server Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

USB ASCII Features

Operation Modes: Device to PLC only
Maximum Number of Devices Supported: 2
ASCII Device Interfaces: USB
Maximum Number of ASCII Characters Transferred: 1024
Delimiter Processing: Incoming delimiters automatically removed
Parsing: Parse string of ASCII data in up to 20 segments by delimiter or offset

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.