Connect Modbus RTU Slaves to BACnet MS/TP

Connect Modbus RTU Slaves to BACnet MS/TP Responders

SKU: 460MMBM

460MMBM

$NZD 1,309.73 - $NZD 1,558.46

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Connect Modbus RTU Slaves to BACnet MS/TP Devices
The 460MMBM moves data between a network of up to 32 Modbus RTU Slaves and up to 32 BACnet MS/TP devices.

With the 460MMBM you’re mapping Modbus coil and register data directly to BACnet MS/TP as binary and analog values.

How Do I Use 460MMBM-N34 in My Application?
Modbus register data is mapped to BACnet analog objects and Modbus coil data is mapped to binary objects. The only additional piece required for BACnet is adding meta data which is nothing more than an ASCII description of each object.

It really is that simple.

Why Use Real Time Automation as a Gateway Supplier?
While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA. When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

Try the RTA difference today.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

BACnet MS/TP Master Features

BACnet/ MS/TP Operation Modes: BACnet MS/TP Master Initiator
Supported Object Types: Device, Binary, Analog, Multi-State, Character String Value
Supported Service Codes: Read Property-A, Read Property Multiple-A, Write Property-A, Write Property
Multiple-A, Device Dynamic Binding-A
Maximum Connections: 32
Number Read/Write Scan Lines per Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 128 Total Objects

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.

460MMBM-N34
DATASHEET  USERGUIDE
460MMBM-N700
DATASHEET  USERGUIDE
460MMBM-NNA4
DATASHEET  USERGUIDE