Connect a Modbus RTU Slaves to a Modbus TCP/IP Client

Easily connect up to 32 Modbus RTU slave to a Modbus TCP/IP controller

SKU: 460MSMM

460MSMM

$NZD 1,346.75 - $NZD 1,916.42

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Get Your Modbus RTU Slave Devices Connected to a Modbus TCP/IP Client

The 460MSMM moves data between up to 32 Modbus RTU Slave devices and a Modbus TCP/IP Client device.

Best of all the product is made in the USA, is always in stock and comes with a 5 year warranty.

How Do I Use the 460MSMM in My Application?

To your Modbus TCP/IP Client device the gateway will look like any other Modbus TCP/IP Server. To your Modbus RTU Slaves the gateway acts as a Modbus RTU Master. In the gateway you configure what data it will read and write from the Modbus TCP/IP Client and each Slave device connection.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified with up to 3 mathematic functions. Add 4 to a value, multiply by 4 and divide by 10 with ease.

Why Use Real Time Automation as a Gateway Supplier?

The 460MSMM provides an option to access Modbus RTU Slave devices on your Modbus TCP/IP network. While there are certainly a number of other companies offering stand alone gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations, even if that means recommending someone else’s solution. When you get support, it is from an engineer who had a hand in the product’s development, and that doesn’t require a ticket or 24 hour wait. We are unashamed of the fact that we are a smaller company because, that means, you mean more to us. Try the RTA difference today!

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus RTU Master Features

Modbus Operation Modes: Modbus RTU Master
Function Codes Supported: 1, 2, 3, 4, 5, 6, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus RTU Slave Devices: 32
Number Read/Write Scan Lines per RTU Slave Device: 200 Total - 100 reads & 100 writes
Scan Line Support: Up to 125 Registers or 512 Coils

Modbus TCP/IP Server Features

Modbus Operation Modes: Modbus TCP/IP Server
Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers

Gateway Security
You can configure up to nine different users with access to diagnostic and configuration screens.

Alarming
Set <, <=, >=, >, ==, !=, and Change-of-State rules on any data moving through the gateway. If alarm rule is triggered an email notification can be sent.

Translation Table
Allows for data manipulation during protocol translation. Scaling and other data format changes can occur in the gateway.

Status and Counters
Protocol specific status, counters and error messages are accessible within the gateways diagnostics page. They can also be delivered to a connected device.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol specific messages & error messages.

460MSMM-N2E
DATASHEET  USERGUIDE
460MSMM-N2EW
DATASHEET  USERGUIDE
460MSMM-N34
DATASHEET  USERGUIDE
460MSMM-N700
DATASHEET  USERGUIDE
460MSMM-NNA1
DATASHEET  USERGUIDE
460MSMM-NNA4
DATASHEET  USERGUIDE