Modbus TCP/IP Client to Siemens S7 PLC

Connect your Modbus TCP/IP Client Directly to the Data Table of your Siemens S7 PLC.

SKU: 460MSSC

460MSSC

$NZD 1,356.26 - $NZD 1,929.93

Clear

Please note, site orders are made via credit card. Please contact sales@techstep.co.nz if you require support to purchase directly.

Product Description

Get Your Modbus TCP/IP Client Connected Directly to the Data Table of your Siemens S7 PLC

The 460MSSC connects a Modbus TCP/IP Client device and up to 5 Siemens S7 PLCs.

Best of all, the product is Made in the USA, is always in stock and comes with a 5-year warranty.

How do I use 460MSSC in my application?

You allocate two memory blocks in your Siemens S7 PLC. One area is a user-defined set of Output addresses sending data to your Modbus TCP/IP Client. The other is Input only data receiving data from your Modbus TCP/IP Client.

It’s really that simple. Need to modify your data as it passes from one protocol to the other? No problem. Each data mapping you apply can be modified.

Why Use Real Time Automation as a Gateway Supplier?

While there are certainly other companies offering protocol gateways, there is no one who provides the level of support and service that you receive from RTA.

When you call, a live person answers the phone. When you talk with sales, you will get honest answers and recommendations. When you get support, it is from an engineer who had a hand in the product’s development, and support doesn’t require a ticket or 24-hour wait.

  • Manual
  • 3’ power cable with flying leads
  • 5-year hardware warranty
  • IPSetup software — automatically locates RTA gateway on the network
  • Unlimited firmware feature upgrades for life
  • CAT5 cross over cable for direct connection to PC during programming
  • Complete, unlimited access to our industry leading support staff

Modbus TCP/IP Server Features

Modbus Operation Modes: Modbus TCP/IP Server
Function Codes Supported: 1, 2, 3, 4, 5, 6, 7, 15 & 16
Swapping: Byte and Word Swapping
Maximum Modbus TCP/IP Client Connections: 10
Contiguous Data Areas: 200 Total - 100 reads & 100 writes
Data Area Limits: 500 Contiguous Coils or 500 Contiguous Registers

S7 Client Features

PLC Support: S7 300/400/1200/1500
Maximum Number of PLCs Supported: 5
Maximum Number of Inputs per PLC: 150
Maximum Number of Outputs per PLC: 150
Array Support: Yes, for all data types
Supported Data Types: 8Bit Int, 16Bit Int, 32Bit Int, 32Bit Float, Bool and String

Gateway Security
You can configure a user with access to diagnostic and configuration screens.

Status and Counters
Protocol-specific status, counters and error messages are accessible within the gateway's diagnostics page.

Diagnostic Logging Page
Allows users to see and log start up sequences, protocol-specific messages and error messages.

460MSSC-N2E
DATASHEET  USERGUIDE
460MSSC-N2EW
DATASHEET  USERGUIDE
460MSSC-N34
DATASHEET  USERGUIDE
460MSSC-NNA1
DATASHEET  USERGUIDE